G4T5 Germicidal UV Fluorescent Lamp
G4T5 4W F4T5/GL
Your lamp may look slightly different!

$4.50 Each

Lot of 3-$12.00

Box of 10-$30.00

Germicidal Lamp Handling Warning

Lamps ordered will be shipped the next day by USPS Priority Mail or UPS. Large orders may qualify for a discount and may not qualify for next day shipment. If you do not know what lamp you require or for lamps not listed, email your request or call 336-882-2854. To order, please use our online order form, secure shopping cart below or call 800-692-3051.


Click below to order using our secure shopping cart.

G4T5 Lamp

Lot of 3 G4T5 Lamps

Box of 10 G4T5 Lamps

Wattage: 4W, 4 Watt Watts
Glass: T-5, T5 Clear
Base: G5 BiPin
UV Emission: 254nm
Maximum Overall Length: 6", 6 Inches, 152mm
8.3uW/cm2 at 1M

Average Rated Life: 5,000 hours

FS-5
Starterlampstarterfs5.html
If you are experiencing slow start times or the new lamp does not work you may need a new starter.
You can purchase the starter for this lamp at FS-5 Fluorescent Starter with Condenser.

Lamp emits UV rays of 254nm and can kill most germs and microorganisms. Emits no ozone.

Alternate Part Numbers: G4T5/G, Ultraviolet Germicidal, AU/LG04T5, 363713, TUV4T5, FG4T5, Sterilamp®, GE 15872, 3000013, Sankyo Denki, Galaxy GXG4T5 22116, LUMINCO LMG4T5DC, Sunlite, 10-046, 990-1040-01, UVP 34000301, 700170-STG, F 4W GL, F4WGL, S4WGL, EcoQuest P/N US70059, 70059, UVC, G4T5/G, 2W4S15W-2135, TUV 4W/G4T5, WHG4T54W, 14-00013-002, Made in Hungary, 20713497 G, OZ4T5, WHG4T5 4W, GC095, B139, 14-0013-002, G C095, 14-00013-002, G C005, GC054, 448

Germicidal lamps are clear with special UV transmitting glass. For use in sterilizers and air and water purifiers. This is an ultraviolet C (253.7 nm wavelength) bulb for use in sterilization, water and air purification and surface disinfection. Used in the Forming and Disinfection of Contact Lenses. Used in UV Sterilizers for Fish Aquariums and Ponds. Fixed wavelength spectrophotometer detector. Germicidal lamps allow 253.7nm UV-C radiation from the mercury discharge to pass through the glass thus penetrating and inactivating the DNA of most micro-organisms.

Warning: Avoid direct exposure of eyes and skin under germicidal lamps. To prevent possible serious injury, eyes and skin should not be exposed to direct or reflected ultraviolet power emitted by this lamp. This lamp is in Risk Group 3 per ANSI/IESNA RP-27.3-96. Adequate protection should be provided by clothing, gloves, opaque materials, and ordinary window glass. Although this lamp will operate in standard fluorescent fixtures, it should not be used for general lighting applications.

Go to our Germicidal Safety Sheet for more lamp handling details.
Note: This lamp contains Mercury. Manage in accord with disposal laws. See www.lamprecycle.org.

Equipment that uses this lamp:

Trident, Vectron, Tetra, Hozelock and Cipro
Jaycar
Jameco
Premier T-12

AquaStar™
UV Portable Water Purifier
AquaStar Plus!

DATARASE II ACT EPROM eraser

CH Lighting
F4T5/GL

Dry and Store
Global Hearing Aid Dehumidifier
Professional Conditioning System

Ecoquest
Fresh Air
#us70059 14-00013-002 B138

Edenpure
Table Top Unit
EdenPURE Air Clean
Eden PURE WGEP1000 Table Top Unit, WGEP-1000
Eden Pure G-7, G7 Air Filtration System

Eprom Eraser
ME5E
ME5
Model LER121A, LER-121A

Forensic UV Lights
CUV100TS
772SW
772ADC
774SW
782UV
785UV
782ADC

Fresh Air
1.5

GreenAir
Air Purifier

Hybec

Kandolite
G4T5

LabAlliance Lab Alliance
HPLC Fixed Wavelength Detector

Omnipure Pacific UV Systems & Accessories
OPP-UV4W 1/2 GPM System

PI-KEM
KW-4AC

Puratron

Purebrush
Anti-bacterial toothbrush purifier
Purebrush Ultra Violet Light Replacement Bulbs

Raytech
SW-4, LS-7, PP-S, PP-FS and M-FS
LS-2 UV Instrument

Sankyo Denki
Esencia Bio ESA-400 Toothbrush Sterilizer

Spectronics
BLE-2537S

Turner
Model 10A Fluorometer

Universal
Hot Towel Warmer Cabby, Cabi
Hotcabi U.V. Sterilizer
Pro Hotcab

UVP
UVS-11, M-14, UVSL-25, UVG-11, UVGL-25 and UVG-4

Cross reference information is designed to help you find the lamp you need for your application. We do not verify the accuracy of this information. You are responsible for ordering the correct lamp you need and we make every attempt to help you in that process. We recommend that you confirm the information with the equipment manufacturer before ordering. 

Replacement Light Bulbs
328-101 Habersham Road
High Point, NC 27260
336-882-BULB (2852)

Order Line:  800-692-3051
Technical Support Line: 336-882-2854
Fax Line: 336-882-2819

Hours: 9 AM to 7 PM EST Monday through Friday

Sales: Address changes, invoice copies, tracking and delivery confirmation numbers, order status, product availability, payment options, shipping quotes, returns, damage claims
336-882-2852
sales@replacementlightbulbs.com

Technical Support: Help finding a product not listed, determining the correct lamp for your application, lamp handling and premature lamp failures
336-882-2854
support@replacementlightbulbs.com

International Orders: Large international orders that require special shipping arrangements and quotes
in@replacementlightbulbs.com

If you have compliments, complaints, suggestions, or help with areas not listed above please contact:

Ron Miller
General Manager

ron@replacementlightbulbs.com

 

lamp light bulb bulbs lamps eiko