Ushio EKE/HC 21V 150W High Color Temperature Light Bulb Replacement Lamp
Ushio EKE/HC 21V 150W High Color Temperature Light Bulb Replacement Lamp

91 Remaining In Stock

Ushio $25.00 Each

Lamps ordered will generally be shipped the next business day by USPS Priority Mail or UPS, check here for Shipping Information. Large orders may qualify for a discount and may not qualify for next day shipment. If you do not know what lamp you require or for lamps not listed, email your request or call 336-882-2854. To order, please use our secure shopping cart or call 336-882-2852 or 800-692-3051. Click to go to our Home Page and View Cart.

Volts: 21V
Watts: 150W
Life: 200 Hours
Tungton Halogen
Maximum Length: 1.75"
Filament: CC-6
Base: GX 5.3, GX5.3
Reflector Type: MR16, MR-16, 50 DICH
Temperature: 4200°K

Alternate Part Numbers: JCR21V-150W Lamp, 1003004, 20094142, 9586, EKE-HC

This 150 watt, 21 volt halogen light features a 2-pin base and reflector used in medical instruments. Bilirubin, photo curing and photo therapy bulb. Also used in 8mm projectors, and fiber optics. High output lamp for most fiber optic applications. Fiber optic lamps used in fiberstar lighting boxes and many diferent types of fiber optical lighting sorces for swimming pools, walk ways and displays. These Light bulbs include halogens and metal halides that produce intense light for use in solid or stranded fiber optics. Extra-Oral/Photo Curing/Fiberoptic Handpiece.

HC Lamp Option

Standard 3200K Lamp vs 4200K High Color Temperature Lamp

3200°K EKE Standard Lamp
4200°K EKE High Color Temperature Lamp

KEY BENEFITS
NO ‘Red Loading’
Improved white balance
1000°K Color Temperature Increase over standard lamps
Higher Output than using Color Correction Filters

High Color Temperature Lamp (EKE-HC) The natural spectral output is modified in such a way as to increase the blue content and reduce the red content of the lamp. The net result is a lamp that provides much “whiter light” with a color temperature of 4200°K. This lamp provides much truer colors for cameras that tend to be red sensitive, and is a must for color camera applications.

Note: These lamps cannot be used in standard lightsources without system recalibration. Contact the factory for details.

APPLICATIONS
Lightsources
CMOS Sensor Calibration
Automotive Fuseblock Verification
InteriorAutomotive Component Inspection
Color Machine Vision
Paint Color Verification
Inkjet Cartridge Verification
Biotechnology

Alpha 1501 150-watt quartz halogen illuminator
Blue Light Industries Model 5410 Fiber Optic Illuminator
Bausch & Lomb Equipment Microscope 31-31-52

CHIU Technical Corporation

FO-150R, FO-150 DPHM Regulated Fiberoptic Illuminator

CoolspotTM II Double
CoolspotTM II Single Ceiling
CoolspotTM II / Outpatient® II with FastracTM

Dolen Jenner

Fiber Lite 180 High Intensity Illuminator
Model 180 Light Source
Fiberlite MI-150
Model 170-D, 170D
DC-Regulated Fiber Optic Illuminator Model PL-900
Fiber Optic Illuminator Model PL-800

Fisher/Westover brand fiber optic 150W light source

High Intensity FO-150 Series F0-150 (with rotary dimmer) and FO-150 DPHM (with diaphragm)

Illumination Techologies, Inc.

3900-DD Dirty Dog IT Industrial Lightsource

Intralux 5000-1, 6000-1, NCL 150 & V-Lux 1000
Intralux 5000-1 20V/150W
Intralux 6000-1 20V/150W
Intralux 5000-1 Dual 20V/150W

KSE-Texas, Inc.

Millennium K2000

Micro-Lite FL 3000 series 150 watt halogen light boxes

Mille Luce

Model M1000 Fiber Optic Illuminator
OPTISPEC MP35030 LIGHT SOURCE. 150w Light Source, ACE #65336
Scienscope Fiber Optic Microscope Illuminator IL-88-FOI
SCI-CAN Dual-Lux II Illuminator
SCI CAN Dual Lux III Illuminator

StockerYale, Inc.

Mille Luce Fiber Optic Illuminator Model M1000
Molte Luce Model M300

Surgical Light CoolSpot II

Techniquip

Fiber Optic Illuminator FOI 150
Techni-Quip Fiber Optic Illuminator Model T-Q/FOI-IV
Model 21AC, 21DC
Technibeam 1000

Cross reference information is designed to help you find the correct lamp for your application. We do not verify the accuracy of this information. You are responsible for ordering the correct lamp and we make every attempt to help you in that process. We recommend that you confirm the information with the equipment manufacturer before ordering.

Replacementlightbulbs.com
800 Burton Avenue, Suite 107
High Point, NC 27262
336-882-BULB (2852)

Order Line: 800-692-3051
Technical Support Line: 336-882-2854
Fax Line: 336-882-2819

Hours: 8 AM to 4 PM EST Monday through Friday

Sales: Address changes, invoice copies, tracking and delivery confirmation numbers, order status, product availability, payment options, shipping quotes, returns, damage claims
336-882-2852
sales@replacementlightbulbs.com

Technical Support: Help finding a product not listed, determining the correct lamp for your application, lamp handling and premature lamp failures
336-882-2854
support@replacementlightbulbs.com

International Orders: Large international orders that require special shipping arrangements and quotes
in@replacementlightbulbs.com

If you have compliments, complaints, suggestions, or help with areas not listed above please contact:

Ron Miller
General Manager

ron@replacementlightbulbs.com