Wattage: 5W, 5 Watt Watts
Nominal Voltage: 35V
Construction Voltage: 35V
Glass: Duo-Tube, T-5, T5 Clear, UV Transmitting Glass
Base: G23 BiPin
UV Emission: 254nm
UV-C Output: 1.3W
Maximum Overall Length: 108mm
Sample Measured Length: 4.1", 4.1 Inches, 104mm
Average Rated Life: 8,000 Hours
Burn Position: Any, Universal
Special Feature: UV irradiance 253.7 nm measured at a distance of 1 m at mid-lamp level, at 20 ° C ambient temperature, free-burning. Between 0.3…3.0 m, the irradiance is inversely proportional to the square of the distance
Lamp emits UV rays of 254nm and can kill most germs and
microorganisms. Emits no ozone.
Alternate Part Numbers: Philips PLS5W/TUV,
PL-S 5W/TUV, FLS/5W, GBX5/UVC, GPX5, GLS/5W, GCF5DS/G23/SE/OF, HNS-S-5W, Osram Puritec, 23396-0, 23396, Light Tech Light Sources LTC5W/G23, Sankyo Denki GPX5, Philips 38186-3, 381863, PL-S 5W/2P, 34020, Ushio 3000321, GBX5-PR, PUVH2305, 820109504, 600300307443, AUVC-5W, GE 40695, TUV PL-S 5W/2P, ZW5D12W-H85
Germicidal lamps are clear with
special UV transmitting glass.
For use in sterilizers and air and water purifiers.
This is an ultraviolet C (253.7 nm wavelength) bulb for use in
sterilization, water and air purification and surface disinfection.
Used in the Forming and Disinfection of Contact Lenses. Used in UV
Sterilizers for Fish Aquariums and Ponds. Fixed wavelength
spectrophotometer detector. Germicidal lamps allow 253.7nm UV-C
radiation from the mercury discharge to pass through the glass thus
penetrating and inactivating the DNA of most micro-organisms.
Warning:
Avoid direct exposure of eyes and skin under germicidal lamps. To
prevent possible serious injury, eyes and skin should not be exposed to
direct or reflected ultraviolet power emitted by this lamp. This lamp
is in Risk Group 3 per ANSI/IESNA RP-27.3-96. Adequate protection
should be provided by clothing, gloves, opaque materials, and ordinary
window glass. Although this lamp will operate in standard fluorescent
fixtures, it should not be used for general lighting applications.
Go to our Germicidal Safety Sheet for
more lamp handling details.
Note: This lamp contains Mercury. Manage in accord with disposal laws.
See www.lamprecycle.org.
Aqua Medic
Helix Max 80805 UV Sanitizer
Helix Max 5
AquaTop
PFUV-15, SP5UV
Boyu
Clear Stream
UV600 Filter, UV 600
Comodity Axis
VIAAQUA Terminator, Via Aqua
Coral Life
Fishmate
Fish Mate
AN264 UV Sanitizer
500 Pressurized UV+Bio Pond Filter
Hozelock Cyprio
Bioforce 250
Bioforce 500
Easy Clear 500
UVC 1311
UVC 1312
UVC 1326
Vorton 500
JBJ
Submariner
Jebao
PU-13, CF-10, CF-20, CF-30, PF-20, PF-30
Jebo
13W UV Sanitizer
PEAK UV PCO Air Purifier
Luniaction
NSE5-220-G
NSE5-220G
PL1H05GER-220G23
PL1H05GER110G23
PL1H05GER220G23
Oceanic
BioCube Mini 5W UV
Oransi Finn
Purifier
Pond Boss
ReSun
13W UV Sanitizer
Sunsun
CUV-13, CPF-180, CPF-250 Via Aqua Terminator Multi Skimmer
Tetra
L105
Grech
Green UV Sterilizer Mini
GreenFree UV Mini Pond Clarifier
Perfect
Pond
PLS5
Tetrapond
PLS5
UV Mini Pond Clarifier
UV5
Tetratech
25075 UV5
Thera Pure, Therapure
101M
201M
TPP2010
TPP201M Hepa Purifier
TMC
Clear Stream 600 Filter with UV
Unimax
Pro 150
Via Aqua
EF-3000UVC Pond Filter
Vorton
500
Bioforce Eco
Cross reference information is designed to help you find the
correct
lamp for your application. We do not verify the accuracy of this
information.
You are responsible for ordering the correct lamp and we make
every attempt to help you in that process. We recommend that you
confirm
the information with the equipment manufacturer before ordering.
Replacementlightbulbs.com
800 Burton Avenue, Suite 107
High Point, NC 27262 336-882-BULB (2852)
Order Line: 800-692-3051
Technical Support Line: 336-882-2854
Fax Line: 336-882-2819
Hours: 8 AM to 4 PM EST Monday through Friday
Sales: Address
changes, invoice copies, tracking and delivery confirmation numbers,
order status, product availability, payment options, shipping quotes,
returns, damage claims
336-882-2852
sales@replacementlightbulbs.com
Technical Support: Help
finding a product not listed, determining the correct lamp for your
application, lamp handling and premature lamp failures
336-882-2854
support@replacementlightbulbs.com
International Orders:
Large international orders that require special shipping arrangements
and quotes
in@replacementlightbulbs.com
If you have compliments, complaints, suggestions, or help with
areas not listed above please contact:
Ron Miller
General Manager
ron@replacementlightbulbs.com
|